International Morse code timing uses a dot as its unit. A dash is three units, an internal gap one, a letter gap three and a word gap seven. Words per minute changes the unit duration without changing the standard ratios.
.--. .- .-. .. ...
The five timing rules
The dot and dash are active pulses. The other three rules describe silent intervals. Do not add a one-unit internal gap on top of the three-unit letter gap: the letter gap replaces it. Likewise, a seven-unit word gap replaces the letter gap at a word boundary.
| Element | Units |
|---|---|
| Dot | 1 |
| Dash | 3 |
| Internal silence | 1 |
| Letter silence | 3 |
| Word silence | 7 |
Calculate the duration of a character
Count the dots, dashes and internal gaps. A has one dot, one dash and one gap, totaling five units. The digit 1 has one dot, four dashes and four gaps, totaling 17 units. The total does not include a trailing silence. Compare A with ET: the active signals are the same, but ET contains a three-unit gap and lasts seven units.
What PARIS means for WPM
The reference word PARIS including its following word gap occupies 50 units. One minute divided by 50 and by the target WPM gives the dot length in seconds: 1.2 / WPM. In milliseconds it is 1200 / WPM. This is a standard calibration word rather than a promise that every word lasts the same time.
| WPM | Dot (ms) | Dash (ms) | Letter gap (ms) | Word gap (ms) |
|---|---|---|---|---|
| 5 | 240.0 | 720.0 | 720.0 | 1680.0 |
| 10 | 120.0 | 360.0 | 360.0 | 840.0 |
| 15 | 80.0 | 240.0 | 240.0 | 560.0 |
| 20 | 60.0 | 180.0 | 180.0 | 420.0 |
| 25 | 48.0 | 144.0 | 144.0 | 336.0 |
Character speed versus effective speed
Farnsworth timing keeps the individual character at a relatively fast rate, while extending the gaps between characters and words to lower effective message speed. For example, 20 WPM character speed and 5 WPM effective speed retains a 60 ms dot, but the between-character spacing is larger than standard 180 ms. Do not use 1200 divided by effective WPM to calculate its dot length.
Worked message calculations
To find a message duration, add each character duration, three units for every adjacent letter gap, and seven units for each word boundary. Do not include a trailing gap unless your application requires it. HELLO has a different duration from PARIS, even at the same nominal WPM.
| Text | Morse code | Time units |
|---|---|---|
| PARIS | .--. .- .-. .. ... | 43 |
| HELLO | .... . .-.. .-.. --- | 49 |
| HI THERE | .... .. / - .... . .-. . | 51 |
| 11 | .---- .---- | 37 |
Tone frequency and audio quality
Pitch in hertz is independent of speed. Use a comfortable audible pitch, a moderate volume and a clean tone. A brief rise and fall at each pulse edge reduces harsh clicks, provided it does not obscure the signal timing. Listen to familiar patterns at several speeds and check that the ratios remain unchanged.
Draw the timing before you calculate it
A Morse signal consists of alternating active pulses and silent intervals. A dot lasts one unit and a dash three. The silence within one character lasts one unit; between two characters it lasts three; between two words it lasts seven. These gaps replace each other. There is no extra one-unit silence added on top of a letter gap, and there is no additional letter gap added on top of a word gap. This matters when implementing a player or measuring a recording.
Take A (.-). Its first pulse occupies units 0–1, its internal gap units 1–2, and its dash units 2–5. If E follows, its dot starts at unit 8, after the three-unit character gap. If E begins a new word, its dot starts at unit 12, after the seven-unit word gap. The signal itself has not changed; the following silence communicates the boundary. A visual timing diagram should show pulse widths and gap widths at the same scale. A decorative line of dots and dashes is not a timing diagram unless those proportions are accurately represented.
Calculate a complete message using PARIS timing
Under the conventional PARIS reference, one standard word including its following gap occupies 50 units. At 20 WPM, a reference word takes three seconds, so each unit is 60 milliseconds. For a character with d dots, h dashes and n total elements, its duration in units is d + 3h + (n−1). The final expression counts only internal gaps. For a full message, add the character durations, three units for each adjacent pair in the same word, and seven units for each word boundary. Add a trailing gap only if the measurement definition requires one.
Consider HELLO. Its character durations are H=7, E=1, L=9, L=9 and O=11. Four letter gaps add twelve units. The total is 49 units, or 2.94 seconds at 20 WPM without a trailing gap. By contrast, PARIS itself occupies 43 units without the final word gap. Nominal WPM is a calibration rather than an assertion that all words have exactly the same duration. A message rich in long letters or digits can take more time than an equal-length message with short letters.
How Farnsworth spacing differs from slowing every element
When character speed is 20 WPM, dots still last 60 milliseconds under Farnsworth training even if the effective speed is lower. The trainer inserts larger gaps between letters and words. That allows time to recognize a complete rhythm before the next one arrives. A standard speed setting of 5 WPM, on the other hand, makes the dot itself 240 milliseconds. These two experiences are not equivalent. The slower character may be easier to count, while the faster character with additional spacing allows a learner to recognize its rhythm more directly.
The precise spacing calculation depends on the reference-word convention. In a PARIS-based proportional spacing implementation, 31 units are devoted to the characters including internal gaps and 19 units to four letter gaps plus a trailing word gap. With character speed C and target effective speed E, the remaining spacing time per reference word is 60/E − 31×1.2/C seconds. Divide that by 19 to obtain the extended spacing unit. For C=20 and E=10, this gives about 218 milliseconds per spacing unit; the letter and word gaps are about 654 and 1,525 milliseconds. These illustrative values should not be applied to a trainer using a different spacing method. The built-in article player uses standard timing, not separate Farnsworth controls.
Test and troubleshoot timing in a real recording
Use a familiar reference pattern before analyzing unknown audio. Play E and T at the same speed and compare the active durations. Then play A and ET; the active signal durations are the same, but the silence differs. If all the pulses seem too short, check the selected WPM. If the pulses have the correct lengths but letters merge, measure the gaps. If dashes appear as dots, check both the duration ratio and the threshold used by the audio decoder. Keep a note of whether a displayed measurement includes a trailing gap so that you do not compare two different definitions of duration.
Worked examples and an answer key
| Text to encode | Morse code | Time units | At 20 WPM |
|---|---|---|---|
| A | .- | 5 | 0.30 s |
| ET | . - | 7 | 0.42 s |
| PARIS | .--. .- .-. .. ... | 43 | 2.58 s |
| HELLO | .... . .-.. .-.. --- | 49 | 2.94 s |
| HI THERE | .... .. / - .... . .-. . | 51 | 3.06 s |
| 11 | .---- .---- | 37 | 2.22 s |
Cover the first column and decode the groups. For an auditory exercise, ask a partner to play the same items in an unfamiliar order using the translator, then compare your written answers. The durations exclude any trailing pause.
| Prompt | Morse code |
|---|---|
| 1 | . - |
| 2 | .--. .- .-. .. ... |
| 3 | .... . .-.. .-.. --- |
| 4 | .... .. / - .... . .-. . |
| 5 | .---- .---- |
| 6 | .- |
Check the decoding answers
ET · PARIS · HELLO · HI THERE · 11 · A
Measure the gaps as well as the active tones
A timing measurement should begin at the onset of the first pulse and end at the end of the final pulse. If a player adds silence before or after a group, that extra silence is not part of the character duration. On a waveform display, select the actual active group before comparing its length to the calculated value. A one-character test such as A is convenient because it contains both pulse lengths and one internal gap.
For a two-character test, compare AA with A A. The first example uses a three-unit character gap between two identical five-unit groups, while the second uses a seven-unit word gap. At 20 WPM, each unit is 60 milliseconds, so the group lengths are 0.78 seconds and 1.02 seconds respectively. The four-unit difference comes entirely from the boundary. Testing both patterns exposes a player that incorrectly treats every space as the same length.
When using Farnsworth timing, the measurement should also distinguish the character speed from the effective speed. A correct result may deliberately have longer external pauses than the standard ratio while preserving the character's internal rhythm. Record which mode the generator is using before labeling a timing difference as an error.
Frequently asked questions
What is the dot duration at 20 WPM?
60 milliseconds under standard PARIS timing.
How long is a letter gap?
Three dot units under standard timing.
Does Farnsworth change dot duration?
It preserves the chosen character speed and lengthens the spaces between characters and words.
References and further reading
Continue learning
Use the Morse code translator or test your knowledge with the MorseZone quiz.
From reading to doing.
Translate words, listen to signals, and put your new knowledge into practice.